Zone Rated

Zone Rated Slip Ring

CSA Certified for Class 1, Division 1, Groups C and D locations.

 

Zone Rated BXXP 2-30 Conductor

IEC holds a hazardous location certification from CSA International for the BXXP series of electrical slip rings for use in Class 1, Division 1, Groups C and D locations. The BXXP is available in 2, 4, 6, 8, 10,12, 16, 20, 24 and 30 ring configurations.

iec-corporation-zone-rated

Standard Specifications

Standard Specifications
Operating Current 7.5 amps per ring
Operating Voltage 1,000 VRMS
Electrical Noise 5µV, P-P, BW=10Hz-10kHZ at 8.5 mA, 500rpm
Leakage Resistance 10,000 MΩ (min)
Temperature Range -30°F to 175°F
Enclosure Stainless Steel
Leads 20 AWG TFE covered wire, 2ft long

Options

Options
Current Up to 24 amps per ring
VoltageUp to 2,000 VDC
BandwidthDC to 250 MHz
WireCoax, twisted pair, thermocouple, to customer specs
Wire leadsLonger leads than 2 ft. standard lengths
MountingTo customer specifications
Sample Applications Include:
  • Oil Well Logging
  • Coil Tubing Reels
  • Food Processing
  • Packaging Machines
  • Stress and Torque Readings
  • Defense Applications
  • Temperature Control